Rosemount Oxymitter 4000 In Situ Oxygen Analyzer

the Rosemount Oxymitter 4000 In Situ Oxygen Analyzer with Probe and Xi Advanced Electronics for Safe Areas is cutting-edge and trustworthy equipment used in industrial applications to gauge the oxygen content of flue gas emissions. It is the perfect answer for enhancing combustion processes, cutting fuel costs, and decreasing emissions while maintaining safety thanks to its in-situ design, durable probe, and cutting-edge electronics.

SKU:28443

MME Shopping Event

Hurry and get discounts on Most of MME Products up to 20%

Call for Price

14People watching this product now!

Rosemount Oxymitter 4000 In Situ Oxygen Analyzer with Probe and Xi Advanced Electronics for Safe Areas

To detect the amount of oxygen in flue gas emissions, industrial applications employ the Rosemount Oxymitter 4000 In Situ Oxygen Analyzer with Probe and Xi Advanced Electronics for Safe Areas. In order to optimize combustion processes, cut fuel costs, and reduce emissions, it delivers real-time readings of oxygen levels.

With its in-situ architecture, the OxymitterTM 4000 detects oxygen levels directly in the process stream and produces findings that are accurate and trustworthy. It has a sturdy stainless steel probe that can tolerate challenging conditions, such as extreme heat and corrosive gases, without losing accuracy.

The Oxymitter 4000 comes with Xi Advanced Electronics, which has a user-friendly interface and is simple to operate and connect with current process control systems. It is the perfect answer for applications where safety is essential because it is made to work in secure environments.

Save expense and time

In order to minimize downtime and save expenses overall, the OxymitterTM 4000 is made to be simple to install and maintain. With its automated calibration feature, readings are dependable and precise without the need for operator intervention.

With a variety of choices available to fulfill certain industrial requirements, the instrument is also made to be extremely configurable. This makes it suitable for use in a variety of industrial applications by offering variable probe lengths, diameters, and measurement ranges.

the Rosemount Oxymitter 4000 In Situ Oxygen Analyzer with Probe and Xi Advanced Electronics for Safe Areas is cutting-edge and trustworthy equipment used in industrial applications to gauge the oxygen content of flue gas emissions. It is the perfect answer for enhancing combustion processes, cutting fuel costs, and decreasing emissions while maintaining safety thanks to its in-situ design, durable probe, and cutting-edge electronics.

Rosemount Oxymitter 4000 In Situ Oxygen Analyzer Specifications:

  • Response Time: Up to 8 sec T90
  • Process Temperature Range: Up to 1300 °F (705 °C) or 1922 °F (1050 °C) with optional bypass and jacket
  • Ambient Temperature: -40 to 176 °F (-40 to 80 °C)
  • Dimensions Probe Length Options:  from 18 in (0.46 m) to 18 ft (5.49 m)
  • Communication Protocol: 4-20 mA HART, FOUNDATION Fieldbus
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Rosemount Oxymitter 4000 In Situ Oxygen Analyzer”

Brand

Rosemount

Rosemount

Rosemount is a well-known brand that designs and manufactures handling tools for a variety of industries. The brand was founded in 1956 and has since become a trusted name in process control solutions. The Rosemount product line includes a wide range of measuring devices such as pressure transmitters, temperature sensors, flow meters, level meters, and analytical instruments. These devices are used to monitor and control critical processes in industries such as petroleum, chemical, pharmaceutical, food, and water treatment.

Rosemount

Datasheet

Article

Article

Specifications

Gas detector
Alarm

Two provided – 2 Amperes, 30 Vdc, Form-C

Gas measuring name/range/reso;ution/accurracy

Accuracy in oxidizing conditions: ±0.75% of reading or 0.05% O2, whichever is greater, Accuracy in reducing conditions: ±0.10% of reading, or 0.1% O2, whichever is greater, Lowest detectable limit: 0.02% O2, Net O2 range: Variable 0–10% to 0–40%

Gas type

Oxygen (O2)

Mechanical and General Specifications
Dimensions

Probe length: 18-in. (457 mm) probes, Probe length: 3 ft. (0.91 m) probes, Probe length: 6 ft. (1.83 m) probes

Weight

probe: 16 lb. (7.3 kg), Probe: 21 lb. (9.5 kg), probe: 27 lb. (12.2 kg)

Power

120 to 240 V, ±10% 50/60 Hz

Operating temperature

–40 °F to 185 °F (–40 °C to 70 °C)

Other features of the device

Fully field-repairable, HART communications

Calibration

Presentation of calibration gases matches the normal process to within ±0.02% O

More
Response Time

Up to 8 sec T90