The PCE-ET 5000 Earth Tester is a multifunctional earth resistance meter designed for various applications, including grounding, soil resistance, and lightning conductor testing. This versatile device can perform both 2- and 4-pole resistance measurements and comes equipped with earth spikes for measuring earth resistance. These spikes can be connected to the device using a separate 20-meter cable provided with the unit.

A notable feature of the PCE-ET 5000 is its ability to test the resistance of lightning conductors, which is crucial for ensuring that buildings, like schools or universities, are protected from lightning strikes by verifying that the lightning rods are properly grounded and have the correct resistance values.

PCE-ET 5000 Key Features

  • Mobile use thanks to battery and batteries
  • Data memory for later analysis on the PC
  • Visual connection aid for easy operation
  • Alarm in case of incorrect connection of the measuring line
  • Direct and indirect resistance measurement
  • Interference currents, interference voltages, frequencies

PCE-ET 5000 Specifications

3-pole earth resistance
Test voltage20, 48V AC
Test frequency94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC
Short circuit current250-mA
Test time26 seconds
Probe resistance Rs<100 kΩ
Auxiliary earth resistance Rh<100 kΩ
Resolution0.001 Ω
Measuring range Re0.02 Ω … 300 kΩ
Accuracy± (5% + 10 digits)
Ust< 24V
Fst16 … 400 Hz
The accuracy is ensured in an environment of 0 … 28°C / 32 … 82°F, < 80% RH (non-condensing).
Response time < 15 seconds (Time required to reach the specified accuracy, after the start of the measurement with the average function switched off.)
4-pole grounding resistor
Test voltage20, 48V AC
Test frequency94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC
Short circuit current250-mA
Test time30 seconds
Probe resistance Rs< 100 kΩ
Auxiliary earth resistance Rh< 100 kΩ
Resolution0.001 Ω
Measuring range Re0.02 Ω … 300 kΩ
Accuracy± (5% + 10 digits)
Ust< 24V
Fst16 … 400 Hz
The accuracy is ensured in an environment of 0 … 28°C / 32 … 82°F, < 80% RH (non-condensing).
Response time < 25 seconds (Time required to reach the specified accuracy, after the start of the measurement with the average function switched off.)
3-pole earth resistance with current clamp
Test voltage20, 48V AC
Test frequency94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC
Short circuit current250-mA
Test time26 seconds
Probe resistance Rs< 100 kΩ
Auxiliary earth resistance Rh< 100 kΩ
Resolution0.001 Ω
Measuring range Re0.02 Ω … 20 kΩ
Accuracy± (5% + 10 digits)
Ust< 24V
Fst16 … 400 Hz
The accuracy is ensured in an environment of 0 … 28°C / 32 … 82°F, < 80% RH (non-condensing).
Response time < 25 seconds (Time required to reach the specified accuracy, after the measurement has started with the average function switched off.)
If the current on the current probe is too low, the measurement can be aborted.
4-pole earth resistance with current clamp
Test voltage20, 48V AC
Test frequency94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC
Short circuit current250-mA
Test time26 seconds
Probe resistance Rs< 100 kΩ
Auxiliary earth resistance Rh< 100 kΩ
Resolution0.001 Ω
Measuring range Re0.02 Ω … 20 kΩ
Accuracy± (5% + 10 digits)
Ust< 24V
Fst16 … 400 Hz
The accuracy is ensured in an environment of 0 … 28°C / 32 … 82°F, < 80% RH (non-condensing).
Response time < 25 seconds (Time required to reach the specified accuracy, after the measurement has started with the average function switched off.)
If the current on the current probe is too low, the measurement can be aborted.
Grounding resistor only with current clamps
Test voltage48V AC
Test frequency94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC
Short circuit current250-mA
Test time26 seconds
Measuring range Re0.02 Ω … 150 Ω
Resolution0.001 Ω
Accuracy± (5% + 10 digits)
Ust< 24V
Fst16 … 400 Hz
The accuracy is ensured in an environment of 0 … 28°C / 32 … 82°F, < 80% RH (non-condensing).
Response time < 25 seconds (Time required to reach the specified accuracy, after the measurement has started with the average function switched off.)
If the current on the current probe is too low, the measurement can be aborted.
Soil resistance (removal resistance)
Test voltage20, 48V AC
Test frequency94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC
Short circuit current250-mA
Test time26 seconds
Resolution0.001 Ω * m
Measuring range Re0.02 Ω … 1000 kΩ * m
Accuracy± (5% + 10 digits)
2-pole resistance measurement (AC)
Test voltage20V AC
Test frequency94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC
Short circuit current250-mA
Test time26 seconds
Measuring range Re0.02 Ω … 300 kΩ
Resolution0.001 Ω
Accuracy± (5% + 10 digits)
Ust< 24V
Fst16 … 400 Hz
2-pole resistance measurement (DC)
Test voltage20V DC
Short circuit current250-mA
Test time26 seconds
Measuring range Re0.02 … 3 kΩ
Resolution0.001 Ω
Accuracy± (5% + 10 digits)
Ust< 3V
Fst16 … 400 Hz
4-pole resistance measurement (DC)
Test voltage20V DC
Short circuit current250-mA
Test time26 seconds
Measuring range Re0.02 Ω … 3 kΩ
Resolution0.001 Ω
Accuracy± (5% + 10 digits)
Ust< 3V
Fst16 … 400 Hz
Line compensation
Test voltage20, 48V AC
Test frequency94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC
Short circuit current250-mA
Test time26 seconds
Resolution0.001 Ω
Measuring range Re0.02 Ω … 30 Ω
Accuracy± (3% + 10 digits)
Ust< 24V
Fst16 … 400 Hz
Interference voltage
Measuring range± 50V DC
1 … 50V AC
Resolution0.1V
Accuracy± (5% + 5 digits)
Interference current
Measuring range20-mA … 2 A
Resolution1-mA
Accuracy± (5% + 5 digits)
Interference frequency
Measuring range16 … 400 Hz
Resolution1 Hz
Accuracy± (1% + 10 digits)
Other specifications
Data storage100 readings
Operating conditions0 … 40°C / 32 … 104°F, < 80% RH (non-condensing)
Charge ambient conditions to the battery10 … 40°C / 50 … 104°F, < 80% rh (non-condensing)
Storage conditions-10 … 50°C / 50 … 122°F, < 90% rh (non-condensing)
Storage conditions for the battery-20 … 30°C / -4 … 86°F, < 80% rh (non-condensing)
Storage height< 12,000 m / 39,370 ft
Operating altitude< 2,000 m / 6,561 ft
Clamp diameter51 mm
DisplayBacklit LCD, 9,999 digits
Display measuring range exceeded> LIMIT
Display below measuring range
Measuring frequency earthing resistance / leakage current1 Hz (If the average value function is activated: one value every four seconds)
Measuring frequency voltage measurement2 Hz
Measuring frequency interference voltage4 Hz
Measuring frequency interference frequency1 Hz
Measuring frequency interference current1 Hz
interfacesMeasuring connection: E, ES, S, H, pliers
connection USB-B, charging connection
Power supply batteries6 x 1.5V D LR14 batteries
Power supply battery1 x 7.2V nickel-metal hydride battery pack
Power supply power supplyPrimary: 100 … 240V, 50 … 60 Hz
Secondary: 12V, 3A
Max. Power consumption with power supply15V A
Max. Power consumption with battery or rechargeable battery6V A
Running time in battery modeAbout 5 hours
Running time in the batteryAbout 9 hours (without backlight)
Maximum input voltage
Maximum input voltage relative to earth300V rms (CAT III)
Insulation thickness6880V AC: 15 seconds
Overvoltage protection250V AC between the connections
Dimensions260 x 125 x 280 mm / 10.2 x 4.9 x 11 in
WeightAbout 2.5 kg / 5.5 lbs
StandardizeSafety: EN61010-1: 2001, EN61010-031: 2002
Pollution degree 2, CAT III 300V,
EMC: EN61000-3-2: 2000, IEC61326-1: 1997 A
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “PCE-ET 5000 Earth Tester”

Brand

Pce

PCE

PCE Instruments is a reliable brand that provides a wide range of high-quality measuring tools for industries such as laboratory testing, industrial manufacturing, and environmental monitoring. With a team of highly skilled engineers and scientists, PCE Instruments develops innovative products in-house to ensure quality and precision. The brand has a world-class reputation for reliability, durability, and accuracy.

pce logo brand3

Datasheet

Mme-Pdfs-Image

Specifications