MET ONE NPM 3 Network Particulate Monitor

MET ONE NPM 3 Network Particulate Monitor key features

• Plug & Play Operation
• Seamless Network Integration
• CCS+ COMET Cloud Plus Compatible | Cloud Data Available on any Smart Device
• Ideal for Neighborhood Monitoring, Smart City & IoT Applications
• Field Proven Nephelometer with Filtered Purge Air System
• Automatic Humidity Control
• Weatherproof Enclosure
• Compact, Low Power

(2 customer reviews)
SKU:7658

MME Shopping Event

Hurry and get discounts on Most of MME Products up to 20%

Call for Price

14People watching this product now!

MET ONE NPM 3 Network Particulate Monitor

The NPM 3 Network Particulate Monitor is an advanced instrument designed for accurate and continuous measurement of particulate matter in the air.

The NPM 3 provides increased reliability while requiring less maintenance. It connects to laptops, data loggers, and CCS+ Comet Cloud Modems through a serial connection. Real-time data can be retrieved and analysed immediately, or it can be saved for later examination. To assure safety and accuracy, the monitor has a 5-mW diode laser and a protective optical enclosure. The user-friendly Comet programme from Met One allows for real-time data viewing and logging in.csv format. Calibration is done with 0.6-micron latex microspheres, and a K Factor is required for precise readings. The manufacturing K Factor is 1.0 by default, however it may need to be adjusted if the local particle source changes. A TSP head, Comet software, a mounting bracket, and a hose clamp are included in the kit.

To avail the best prices and purchase Met One brand products in Dubai, we recommend visiting the official website of MME. MME offers a wide range of Met One products at competitive prices, ensuring you get the best value for your investment. With their reliable service and extensive product selection, MME is a trusted destination for those seeking high-quality Met One products in Dubai. Visit their website now to explore their offerings and make your purchase with confidence.

MET ONE NPM 3 FEATURES

  • Plug & Play Operation
  • Seamless Network Integration
  • CCS+ COMET Cloud Plus Compatible | Cloud Data Available on any Smart Device
  • Ideal for Neighborhood Monitoring, Smart City & IoT Applications
  • Field Proven Nephelometer with Filtered Purge Air System
  • Automatic Humidity Control
  • Weatherproof Enclosure
  • Compact, Low Power
  • 24-Month Service Interval
  • Excellent Accuracy & Long-Term Stability
  • Adjustable “K” Factor
  • Low Cost

MET ONE NPM 3 Network Particulate Monitor specifications

  • Measurement Range: 0 to 100 mg/m3 (0 – 100,000 μg/m3)
  • Measurement Sensitivity:0.001 mg/m3
  • Nephelometer Accuracy: ± 5% traceable standard with 0.6μm PSL
  • Particle Size Sensitivity: 0.1 to 100 microns. Optimal sensitivity 0.5 to 10 micron particles.
  • Long Term Stability: 5% with clean optics.
  • Laser Type: Diode Laser 5 mW, 670 nm. Visible red.
5
2 reviews
2
0
0
0
0

2 reviews for MET ONE NPM 3 Network Particulate Monitor

Clear filters
  1. mary

    nice

  2. sara

    MET ONE NPM 3 is good product

Add a review

Brand

Met One

Met One

Met One Instruments, Inc. is in the business of ambient air measurements and air quality monitoring elements that effect every person on earth. Met One Instruments, Inc. was founded in 1989 with the primary purpose of simplifying and improving the user’s experience. The new company placed exceptional customer service and ease of use at the forefront, introducing new products and services well received in the market.

With the company’s increasing reputation for service, reliability, and integrated system solutions, Met One Instruments went through a rapid growth phase. Part of this growth involved Met One’s strategic acquisition of other businesses in the industry, broadening our product offering, core technology, and customer base. All of this helped catapult Met One Instruments, Inc. to a being a global provider.

met one

catalog

Data Sheet

Specifications

particle counter
Concentration range/resolution/accuracy

Measurement Range: 0 to 100 mg/m3 (0 – 100,000 µg/m3), Measurement Sensitivity: 0.001 mg/m3

Flow rate

2.0 liters/minute

Particle size range

0.1 to 100 microns. Optimal sensitivity 0.5 to 10 micron particles

Mechanical and General Specifications
Dimensions

54.6 cm high x 38.1 cm wide x 17.8 cm deep (21.5” x 15” x 7”)

Weight

2.7 kg (6 lbs.)

Power

Input Power: Input: 11 – 40 VDC @ 1.5 A maximum, Power Consumption: 350 mA (no heater) 1.1 A (with heater) @ 15 VDC

Accessories

0.2 micron Purge Filter (PN 580302), 5.0 micron Pump Protection Filter (PN 580345), Serial & Power Cable NPM 2 to CCS Modem 2, P/N 82906, Serial & Power Cable NPM 2 to Logger, P/N 82905, Sharp Cut PM10 P/N SCC 110, Sharp Cut PM2.5 P/N SCC 112, Tripod, P/N 905, Weather Proof Power Supply, P/N 9438-4

Operating temperature

0 to +50°C

Storage temperature

-30°C to +50°C (-22°F to 122°F), Long Term Stability: 5% with clean optics., Pump Type: Brushless Diaphragm

Other features of the device

Laser Type: Diode Laser 5 mW, 670 nm. Visible red

Calibration