Fluke RPM4 Reference Pressure Monitor

The Fluke RPM4 Reference Pressure Monitor stands as a pinnacle of precision and reliability in pressure calibration. Its compact and robust design, versatility in atmospheric pressure and air data instrument measurements, adherence to recommended calibration standards, and user-friendly interface collectively make it an indispensable tool for professionals demanding accurate and dependable pressure readings. Whether in a controlled laboratory environment or challenging field conditions, the RPM4 excels, reflecting Fluke Calibration’s commitment to excellence in measurement technology.

SKU:74044

MME Shopping Event

Hurry and get discounts on Most of MME Products up to 20%

Call for Price

20People watching this product now!

Fluke RPM4 Reference Pressure Monitor

The Fluke RPM4 is a reference pressure monitor instrument demonstrating Fluke Calibration’s commitment to accuracy and dependability in pressure measurement. Despite its compact and durable build, it excels in high-pressure conditions, making it an indispensable tool for advanced pressure calibration tasks. This article will delve into the primary features and applications that set the RPM4 apart in pressure calibration.

Compact Design for Robust Performance

The Fluke RPM4’s compact design is a testament to its versatility and adaptability in various environments. Built to withstand extreme pressure conditions, it offers a robust performance that caters to both laboratory and field settings. This design ensures that the RPM4 remains reliable for professionals seeking precise pressure measurements.

Versatility in Atmospheric Pressure Measurement

The Fluke RPM4 BA100K, a specific configuration of the RPM4, serves as a laboratory-quality barometer. Tailored to measure atmospheric pressure with exceptional performance, the RPM4 BA100K ensures the highest level of accuracy in atmospheric pressure readings.

Specialized Configurations for Air Data Instruments

The Fluke RPM4-AD configuration is designed to measure and display altitude, airspeed units, and more. Its versatility covers air data instruments’ absolute and differential pressure ranges. Whether for fixed-wing or rotary-wing applications, the RPM4-AD stands out as a specialized solution for air data calibration.

Recommended Calibration Standards

To ensure the highest level of accuracy, the RPM4 utilizes recommended calibration standards. For instance, the RPM4 A70M/A20M-AF Q-RPTs are calibrated using a DH Instruments PG7202 piston gauge. This commitment to precision in calibration standards underscores the reliability of the RPM4 in providing accurate pressure measurements.

User-Friendly Interface for Optimal Performance

The Fluke RPM4 is designed with a user-friendly interface, enhancing the overall user experience. This feature streamlines operations, making it easy for technicians to navigate and utilize the instrument effectively. The combination of precision and user-friendly design positions the RPM4 as a leading choice in the field of reference pressure monitors.

Fluke RPM4 Reference Pressure Monitor Specifications:

General

  • Power Requirements: 85 to 264 VAC, 50/60 Hz, 25 VA max and 12 VDC @ 9 Ahr
  • Battery/Charger: 100 to 240 VAC, 50/60 Hz
  • Normal Operating Temperature Range: 15 to 35 °C
  • Vibration: Meets MIL-T-28800D
  • Weight (Typical): 5 kg (11 lb)
  • Dimensions: 10 cm H x 22.7 cm W x 24 cm D (3.9 in. x 8.9 in. x 9.5 in.)
  • Battery/Charger: 8 cm H x 22.5 cm W x 20 cm D (3.1 in. x 8.9 in. x 7.9 in.)
  • Communications Ports: RS232 (COM1, COM2), IEEE-488.2
  • Operating Modes: Absolute, gauge, compound gauge, differential
  • Pressure Range: Vacuum to 280 MPa (40,000 psi)
  • Operating Media: Q-RPTs lower than A7M Gas only, All others Either gas or oil
  • Calibration: NVLAP-accredited
  • Pressure Connections:
    • Up to A70M: 1/8 in. NPT F
    • Above A70M: DH500 (equivalent to AE250C)
  • CE Mark: Available, must be specified

Measured pressure (Q-RPT)

  • Warm-Up Time: 30-minute temperature stabilization recommended from cold power-up
  • Resolution: To 1 ppm, user-adjustable
  • Predicted One Year Stability: ± 0.005 % of reading all ranges and classes
  • Precision: Q-RPTs up to A14M (2,000 psi)
    • Standard Class: ± 0.008 % of reading, or 0.0024% of Q-RPT span, whichever is greater
    • Premium Class: ± 0.005 % of reading, 0.0015% of AutoRanged span or 0.0005% of Q-RPT span, whichever is greater
  • Measurement Uncertainty: Q-RPTs up to A12M (2,000 psi)
    • Standard Class: ± 0.010 % of reading or 0.0030% of Q-RPT span, whichever is greater
    • Premium Class: ± 0.008 % of reading, 0.0024% of AutoRanged span, or 0.0007% of Q-RPT span, whichever is greater
  • Precision: Q-RPTs A20M TO A140M (3,000 to 20,000 psi) ± 0.012 % of reading or 0.0036% of Q-RPT span, whichever is greater
  • Measurement Uncertainty: Q-RPTs A20M TO A140M (3,000 to 20,000 psi) ± 0.013 % of reading or 0.0039% of Q-RPT span, whichever is greater
  • Precision: QRPT’s A200M to A280M (30,000 to 40,000 psi) ± 0.015 % of reading or 0.0045% of Q-RPT span, whichever is greater
  • Measurement Uncertainty: QRPT’s A200M to A280M (30,000 to 40,000 psi) ± 0.018 % of reading or 0.0054% of Q-RPT span, whichever is greater.
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Fluke RPM4 Reference Pressure Monitor”

Brand

Fluke

Fluke Corporation

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products. From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Datasheet

Datasheet

Datasheet

Specifications

pressure pump
connection

Above A70M: DH500 (equivalent to AE250C), Up to A70M: 1/8 in. NPT F

media

Q-RPTs lower than A7M Gas only, All others Either gas or oil

pressure range/resolution/accuracy

Vacuum to 280 MPa (40,000 psi)

Stability

± 0.005 % of reading all ranges and classes

Mechanical and General Specifications
Dimensions

10 cm H x 22.7 cm W x 24 cm D (3.9 in. x 8.9 in. x 9.5 in.)

Weight

5 kg (11 lb)

Power

85 to 264 VAC, 50/60 Hz, 25 VA max and 12 VDC @ 9 Ahr

Operating temperature

15 to 35 °C

Other features of the device

Vibration: Meets MIL-T-28800D

Calibration

NVLAP accredited

More
Communications Ports

RS232 (COM1, COM2), IEEE-488.2

Operating Modes

Absolute, gauge, compound gauge, differential

CE Mark

Available, must be specified

Measured pressure (Q-RPT)

Warm Up Time: 30 minute temperature stabilization recommended from cold power up
Resolution: To 1 ppm, user adjustable
Predicted One Year Stability: ± 0.005 % of reading all ranges and classes
Precision: Q-RPTs up to A14M (2,000 psi)
Standard Class: ± 0.008 % of reading, or 0.0024% of Q-RPT span, whichever is greater
Premium Class: ± 0.005 % of reading, 0.0015% of AutoRanged span or 0.0005% of Q-RPT span, whichever is greater
Measurement Uncertainty: Q-RPTs up to A12M (2,000 psi)
Standard Class: ± 0.010 % of reading or 0.0030% of Q-RPT span, whichever is greater
Premium Class: ± 0.008 % of reading, 0.0024% of AutoRanged span, or 0.0007% of Q-RPT span, whichever is greater
Precision: Q-RPTs A20M TO A140M (3,000 to 20,000 psi) ± 0.012 % of reading or 0.0036% of Q-RPT span, whichever is greater
Measurement Uncertainty: Q-RPTs A20M TO A140M (3,000 to 20,000 psi) ± 0.013 % of reading or 0.0039% of Q-RPT span, whichever is greater
Precision: QRPT’s A200M to A280M (30,000 to 40,000 psi) ± 0.015 % of reading or 0.0045% of Q-RPT span, whichever is greater