Fluke Networks CFP2-Q-ADD-R
Include:
- 1 Versiv 2 Remote
- (2) CertiFiber Pro Quad OLTS modules
- SC/LC EF-compliant MM TRC Kit 50 µm
- SC/LC SM TRC Kit
- TRC Carrying Case
- (2) LC/LC Simplex Adaptors
- (2) HandStraps
- (2) Shoulder Straps
- Large Carry Case
- AC Chargers
- Statement of Calibration and Getting Started Guide. (Requires a Versiv 2 mainframe)
MME Shopping Event
Hurry and get discounts on Most of MME Products up to 20%
Call for Price
Fluke Networks CFP2-Q-ADD-R CertiFiber® Pro Optical Loss Test Set
The Fluke Networks CFP2-Q-ADD-R CertiFiber Pro Quad OLTS Add-On Kit with Remote is a comprehensive set designed to enhance fiber optic testing by integrating with the Versiv 2 mainframe system. This kit is particularly useful for professionals who need to perform advanced fiber optic certification, troubleshooting, and network reliability tests.
Fluke Networks CFP2-Q-ADD-R Key Features
- Optical loss test set with fastest time to certify – two fibers at two wavelengths in under three seconds.
- Encircled Flux compliant as required by ANSI/TIA and ISO/IEC
- Merged Tier 1 (Basic) / Tier 2 (Extended) testing and reporting when paired with OptiFiber® Pro OTDR
- ProjX™ management system ensures all jobs are completed correctly and efficiently
- Optical loss test set provides automatic Pass/Fail analysis to industry standards or custom test limits
- Double ended Pass/Fail certification of fiber optic connector endfaces
- Graphical indication of problem areas on fiber endfaces due to contamination, pits, chips and scratches
- Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
- Taptive™ user interface provides simple, animated guidance to eliminate incorrect reference setup and “negative loss” errors.
- Convenient quad module supports both multimode and singlemode loss testing
- Extended singlemode distance range to 130km
- Optical loss test set with built in Visual Fault Locator
- Analyze test results and create professional test reports using LinkWare™ Management Software
- Compatible with LinkWare™ Live.
Fluke Networks CFP-Q-ADD Specifications
Power Meter Specifications
SPECIFICATION CATEGORY | DETAILS |
---|---|
Input Connector | Interchangeable connector adapter (LC standard, SC, ST, and FC optional) |
Detector Type | InGaAs |
Wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range | 0 dBm to -65 dBm (850 nm); 0 dBm to -70 dBm (other wavelengths) |
Power Measurement Uncertainty | < +/- 5% +/- 32 pW |
Measurement Linearity | < ± 0.1 dB |
Re-calibration Period | 1 year |
Integrated Wi-Fi | Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz) |
Loss/Length Specifications
SPECIFICATION CATEGORY | MULTIMODE MODULES | SINGLEMODE MODULES |
---|---|---|
Testing Speeds | Smart Remote: < 3 sec <br> Far End Source/Loopback: ≤ 2 sec | Same as Multimode |
Input/Output Connectors | Interchangeable (LC, SC, ST, FC) | Same as Multimode |
Launch Condition | Encircled Flux compliant (various standards) | Same as Multimode |
Fiber Types Tested | 50/125 µm, 62.5/125 µm | Singlemode |
Source Type and Wavelengths | LED source 850 nm ± 30 nm, 1300 nm ± 20 nm | Fabry-Perot laser diode 1310 nm ± 20 nm, 1550 nm ± 30 nm |
Maximum Length Measurement | 12 km | 130 km |
Length Measurement Accuracy | ± 1.5 m plus ± 1 % of length | Same as Multimode |
Output Power (Nominal) | ≥ -24 dBm with EF-TRC | ≥ -4 dBm |
Output Power Stability | ± 0.05 dB over 8 hours | ± 0.1 dB over 8 hours |
Visual Fault Locator (VFL) Specifications
SPECIFICATION CATEGORY | DETAILS |
---|---|
Output Power | >-5 dBm to <0 dBm on SMF-28 fiber |
Operating Wavelength | 650 nm nominal |
Output Modes | Continuous wave, Pulsed mode (2 Hz to 3 Hz blink frequency) |
Connector Adapter | 2.5 mm universal |
Laser Safety | Class II CDRH, over operating temperature range |
Environmental Specifications
SPECIFICATION CATEGORY | DETAILS |
---|---|
Operating Temperature | -10° C to 45° C |
Storage Temperature | -10° C to +60° C |
Operating Relative Humidity | 0% to 90% RH up to 35° C; 0% to 70% RH up to 45° C |
Vibration | Random, 2 g, 5 Hz-500 Hz |
Shock | 1 m drop test, with/without module and adapters |
Safety Standards | CSA C22.2 No. 1010.1: 1992, EN 61010-1 1st Edition + Amendments 1, 2 |
Pollution Degree | 2 |
Altitude | Operating: 4,000 m; storage: 12,000 m |
EMC Standards | EN 61326–1 |
You must be logged in to post a review.
Brand
Fluke Networks
Fluke Networks
Fluke Networks is the worldwide leader in certification, troubleshooting, and installation tools for professionals who install and maintain critical network cabling infrastructure. From installing the most advanced data centers to restoring telephone service after a disaster, our combination of legendary reliability and unmatched performance ensure jobs are done efficiently. Fluke is a multi-national corporation headquartered in Everett, Washington, USA. Manufacturing centers are located in the USA, the UK, Asia, and The Netherlands.
Specifications
Related Products
Cisco WS-C2960-8TC-L 2960 Switch
In stock
Reviews
Clear filtersThere are no reviews yet.