Fluke 124B/S Portable Industrial Oscilloscopes (40 MHz)
The Fluke 124B/S Portable Industrial Oscilloscope is a compact, rugged, and versatile instrument designed to meet the needs of industrial maintenance professionals and technicians.
- Fluke 124B portable oscilloscope
- Shielded test leads with black ground leads
- Test lead, black (for grounding)
- Hook clamps (red, blue)
- Banana plug to BNC adapter (black, 1 piece)
- 10:1 voltage probe
- USB angle adapter
- WiFi USB adapter*
- Switching power supply, adapter/battery charger
- Li-ion battery pack
- Padded carry bag
- Magnetic hanging device
- ScopeMeter® software FlukeView® for Windows®
- Protective film
MME Shopping Event
Hurry and get discounts on Most of MME Products up to 20%
Call for Price
Fluke 124BS Industrial Oscilloscopes
The Fluke 124B/S Portable Industrial Oscilloscope is a compact, rugged, and versatile instrument designed to meet the needs of industrial maintenance professionals and technicians. It integrates the functionality of a dual-input digital oscilloscope and a multimeter, making it a comprehensive test tool for a wide range of applications. This model is particularly notable for its 40 MHz oscilloscope bandwidth, which is suitable for a variety of industrial applications.
One of the key features of the Fluke 124B/S is its Connect-and-View™ trigger simplicity, which provides automatic and stable waveform display without the need for manual adjustments. This feature is particularly useful in complex industrial environments where signal patterns can be unpredictable and varied. The IntellaSet™ technology is another standout feature, which automatically and intelligently adjusts numerical readouts based on the measured signal, streamlining the troubleshooting process and making it faster and more efficient.
Fluke 124B/S: Versatile Industrial Oscilloscope with Advanced Recording and Connectivity Features
The Fluke 124B/S also includes a dual-input waveform and meter reading recorder, allowing for the trending of data over extended periods. This is particularly useful for capturing and analyzing intermittent signals or elusive events that can lead to equipment failures. The recorder event detect feature further enhances this capability by capturing and logging intermittent faults on repetitive waveforms up to 4 kHz.
Designed to withstand harsh industrial conditions, the Fluke 124B/S comes with shielded test leads for oscilloscope, resistance, and continuity measurements, ensuring reliable performance in demanding environments. It also offers comprehensive measurement capabilities, including resistance, continuity, diode, capacitance, power measurements (W, VA, VAR, PF, DPF, Hz), voltage, current, and power harmonics, providing a complete insight into the electrical state of health of industrial equipment.
Additionally, the Fluke 124B/S supports connectivity options such as an external optically isolated USB interface for transferring, archiving, and analyzing data. An optional WiFi adapter can be connected to the internal USB port for wireless data transfer to a PC, laptop, or Fluke Connect mobile app, further enhancing its versatility and ease of use. With its robust design, comprehensive measurement capabilities, and advanced features, the Fluke 124B/S Portable Industrial Oscilloscope is an essential tool for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications.
Fluke 124BS Specifications:
Oscilloscope mode | ||
Vertical | ||
Frequency Response – DC coupled | without probes and measuring lines (with BB120) | 123B: DC to 20 MHz (-3 dB) 124B, 125B: DC to 40 MHz (-3 dB) |
with shielded 1:1 measuring cable pair STL120-IV | DC to 12.5 MHz (-3 dB) / DC to 20 MHz (-6 dB) | |
with 10:1 probe VP41 | 123B: DC to 20 MHz (-3 dB) 124B, 125B: DC to 40 MHz (-3 dB) | |
Frequency Response – AC coupled (when ROLL mode off) | without probes and measuring lines | <10Hz (-3dB) |
with shielded 1:1 measuring cable pair STL120-IV | <10Hz (-3dB) | |
with 10:1 probe VP41 | <10Hz (-3dB) | |
Rise time, without probes or | 123B <17.5 ns 124B and 125B < 8.75 ns | |
Input impedance | without probes and measuring lines | 1MΩ//20pF |
with BB120 | 1MΩ//24pF | |
with shielded 1:1 measuring cable pair STL120-IV | 1MΩ//230pF | |
with 10:1 probe VP41 | 5MΩ//15.5pF | |
sensitivity | 5 mV to 200 V/div | |
Analog bandwidth limiter | 10kHz | |
Display modes | A, -A, B, -B | |
Max. input voltage A and B | directly, with measuring cables or VP41 probe | CAT IV 600 Veff |
with BB120 | 600 Veff | |
Max. floating voltage, from each connection to ground | CAT IV 600 Veff | |
Horizontal | ||
Oscilloscope modes | Normal, Single, Roll mode | |
Areas (Normal) | Sampling of repetitive signals | 123B: 20ns to 500ns/Div, |
124B and 125B: 10ns to 500ns/div | ||
Real-time sampling | 1 µs to 5 s/div | |
Single (real time) | 1 µs to 5 s/div | |
Roll mode (real time) | 1 s to 60 s/div | |
Sample rate (for both inputs simultaneously) | Sampling rate (both channels, repeating signals) | up to 4 GS/s |
Real-time sampling 1 s to 60 s/div. | 40MS/s |
Triggering | ||
Display update | Free running when triggered | |
source | AWAY | |
Sensitivity A and B | at DC up to 5 MHz | 0.5 divisions or 5 mV |
at 40MHz | 123B: 4 Div | |
124B and 125B: 1.5 div | ||
at 60MHz | 123B: N/A | |
124B and 125B: 4 Div | ||
Flank | Rising, Falling |
Additional oscilloscope functions | ||
Display modes | Normal | Detects glitches (short disturbance pulses) up to 25 ns and displays an analogue-like afterglow signal form |
smoothing | Removes noise from a waveform | |
Glitch capture off | Does not capture glitches between sample points | |
Envelope | Records and displays the minimum and maximum values of waveforms over time | |
Auto Set (Connect-and-View™) | Constant fully automatic adjustment of amplitude, time base, trigger level, trigger distance and delay time. Manual deactivation by user setting of amplitude, time base or trigger level. |
Probe accuracy +1%. There must be at least one waveform period visible on the display.
Dual channel multimeter | ||
The accuracy of all measurements is between 18 °C and 28 °C within ± (% of the measured value + counting steps of the least significant digit). | ||
Add 0.1 x (specified accuracy) for each °C below 18°C or above 28°C. For voltage measurements with a 10:1 probe, add them together |
Entrance A and Entrance B | ||
DC voltage (VDC) | ||
areas | 500mV, 5V, 50V, 500V, 750V | |
accuracy | ±(0.5% + 5) | |
Common Mode Rejection (CMRR) | >100 dB at DC, >60 dB at 50, 60 or 400 Hz | |
Display scope | 5,000 counting steps | |
True RMS voltage values (V AC and V AC+DC) | ||
areas | 500mV, 5V, 50V, 500V, 750V | |
Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V AC+DC) | ±(1% + 10) |
1Hz to 60Hz (VAC) | ±(1% + 10) | |
Accuracy for 5% to 100% of range (AC or DC coupled) | 60Hz to 20kHz | ±(2.5% + 15) |
DC suppression (VAC only) | >50dB | |
Common Mode Rejection (CMRR) | >100 dB at DC | |
>60 dB at 50, 60, or 400 Hz | ||
Display scope | 5000 counting steps, measured value is independent of the crest factor. | |
peak value | ||
Display types | Max Peak, Min Peak, or Peak to Peak | |
areas | 500mV, 5V, 50V, 500V, 2200V | |
accuracy | Max Peak or Min Peak | 5% of the range end value |
Accuracy peak to peak | 10% of the range end value | |
Display scope | 500 counting steps | |
Frequency (Hz) | ||
areas | 123B: 1Hz, 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz, and 50MHz | |
124B and 125B: 1Hz, 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz and 70MHz | ||
Frequency range | 15 Hz (1 Hz) to 50 MHz with continuous automatic adjustment | |
Accuracy at 1 Hz to 1 MHz | ±(0.5% + 2) | |
Display scope | Display size up to 10,000 | |
revolutions/min. (RPM or min-1) | ||
Maximum value | 50,000 rpm | |
accuracy | ±(0.5% + 2) | |
duty cycle | ||
Area | 2% to 98% | |
Frequency range | 15 Hz (1 Hz) to 30 MHz with continuous automatic adjustment | |
Pulse width | ||
Frequency range | 15 Hz (1 Hz) to 30 MHz with continuous automatic adjustment | |
Display scope | 1000 counting steps | |
Current strength | ||
with current clamp | areas | such as V DC, V AC, V AC+DC or peak value |
Scaling factors | 0.1mV/A, 1mV/A, 10mV/A, 100mV/A, 400mV/A, 1V/A, 10mV/mA | |
accuracy | as with V DC, V AC, V AC+DC, or PEAK (the inaccuracy of the current clamp must be added) | |
Temperature with optional temperature sensor | ||
Area | 200°C/div (200°F/div) | |
Scaling factor | 1mV/°C and 1mV/°F | |
accuracy | as with V DC (the inaccuracy of the temperature sensor must be added) | |
Decibel (dB) | ||
0dBV | 1V | |
0dBm (600Ω /50Ω) | 1 mW related to 600 Ω or 50 Ω | |
dB for | V DC, V AC or V AC+DC | |
Display scope | 1000 counting steps | |
Crest factor | ||
Area | 1 to 10 | |
Display scope | 90 counting steps | |
phase | ||
Types of measurement | A to B, B to A | |
Area | 0 to 359 degrees | |
resolution | 1 degree | |
Power (125B only) | ||
Configurations | 1-phase or 3-phase with symmetrical load (3-phase: only fundamental component, only AUTOSET operation) | |
Power factor (PF) | Ratio between active power and apparent power: 0.00 to 1.00 | |
Active power (watts) | RMS measurements of corresponding samples from input A (voltage) and input B (current) | |
Display scope | 999 counting steps | |
Apparent power (VA) | V eff x A eff | |
Display scope | 999 counting steps | |
Reactive power (VAR) | √((VA)²-W²) | |
Display scope | 999 counting steps | |
Vpwm | ||
Purpose | For measuring pulse width modulated signals, e.g. B. at the outputs of frequency converters | |
principle | Measurements show the effective voltage based on the average of sample points over a range of periods of the fundamental frequency | |
accuracy | as with Veff for sine signals |
Entrance A | ||
Resistance (Ω) | ||
areas | 123B and 124B | 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 30MΩ |
125B | 50Ω, 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 30MΩ | |
accuracy | ± (0.6% + 5), in the range 50 Ω ±(2% + 20) | |
Display scope | 50 Ω to 5 MΩ – 5000 counts, 30 MΩ – 3000 counts | |
measuring current | 0.5 mA to 50 nA, decreasing with larger ranges | |
Open circuit voltage | <4V | |
Continuity test | ||
Acoustic signal | <(30 Ω ± 5 Ω) in the 50 Ω range | |
measuring current | 0.5mA | |
Detection of short circuits | ≥1 ms | |
Diode test | ||
Measuring voltage: | at 0.5 mA | >2.8V |
at idle | <4V | |
measuring current | 0.5mA | |
polarity | + at input A, – at COM | |
capacity | ||
areas | 50nF, 500nF, 5μF, 50μF, 500μF | |
Display scope | 5,000 counting steps | |
measuring current | 500 nA to 0.5 mA, increasing with larger ranges |
Advanced multimeter functions | ||
Zero Set | Setting the actual value as a reference value | |
AutoHold (at A) | Captures a stable measurement result and fixes it on the display. If the measurement result is stable, an acoustic signal sounds. The AutoHold function affects the main measurement display, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals. | |
Fixed decimal point | Activated by pressing the attenuator buttons |
only possible in single-channel mode)
Cursor display (124B and 125B) | ||
Sources | AWAY | |
Single vertical line | Average, minimum and maximum value display | |
Average, minimum and maximum values as well as time since display start (in ROLL mode; measuring device in HOLD mode) | ||
Minimum and maximum value as well as time since display start (in RECORDER mode; measuring device in HOLD mode) | ||
Harmonic values in POWER QUALITY mode. | ||
Two vertical lines | Display of peak-to-peak values, time interval and reciprocal time interval | |
Display of mean, minimum and maximum values as well as time interval (in ROLL mode; measuring device in HOLD mode) | ||
Two horizontal lines | Display high, low and peak-to-peak values | |
Rise or fall time | Transition time, 0% and 100% level (manual or automatic level adjustment; automatic level adjustment | |
accuracy | See Oscilloscope Accuracy |
recorder | ||
The recorder captures measured values in multimeter recorder mode or continuously captures sampling points of the waveforms in oscilloscope recorder mode. The information is stored in internal memory or on an optional SD card (on the 125B or 124B). | ||
The results are displayed as a recorder plotting a graph of minimum and maximum values of measurements over time, or as a waveform display showing all sample points acquired. | ||
Measurements | ||
Measuring speed | Maximum 2 measurements/s | |
Record size (min., max., average) | 2 million measured values for 1 channel | |
Recording period | 2 weeks | |
Maximum number of events | 1024 | |
Waveform recording | ||
Maximum sampling rate | 400,000 sampling points/s | |
Recording space internal memory | 400 million sampling points | |
Recording period internal memory | 15 minutes at 500 μs/div 11 hours at 20 ms/div | |
Recording space on the SD card | 1.5 billion sample points | |
Recording period SD card | 11 hours at 500 μs/div 14 days at 20 ms/div | |
Maximum number of events | 64 |
Include:
- Fluke 124B portable oscilloscope
- Shielded test leads with black ground leads
- Test lead, black (for grounding)
- Hook clamps (red, blue)
- Banana plug to BNC adapter (black, 1 piece)
- 10:1 voltage probe
- USB angle adapter
- WiFi USB adapter*
- Switching power supply, adapter/battery charger
- Li-ion battery pack
- Padded carry bag
- Magnetic hanging device
- ScopeMeter® software FlukeView® for Windows®
- Protective film
You must be logged in to post a review.
Brand
Fluke
Fluke Corporation
Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products. From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.Specifications
Related Products
GW Instek GDS 2204E 200MHz, 4 Channels Digital Storage Oscilloscope
In stock
GW Instek GDS 2102A Digital Storage Oscilloscope, 100MHz, 2 Channel
In stock
GW Instek MDO 2204EX 200MHz 4 Channel Mixed Domin Oscilloscope
In stock
GW Instek GDS 207 70MHz Handheld Digital Oscilloscope
In stock
GW Instek GDS 1102B Oscilloscope
In stock
Reviews
Clear filtersThere are no reviews yet.