The Avo/Megger DCM300E is a High Resolution AC Clamp Meter thats perfect for checking nuisance tripping RCD’s The DCM300E is designed primarily to check earth leakage currents.

(1 customer review)
SKU:3520

MME Shopping Event

Hurry and get discounts on Most of MME Products up to 20%

Call for Price

14People watching this product now!

Megger DCM300E-Earth Leakage Clamp Meter

The Megger DCM300E Earth Leakage Clamp Meter is a specialized tool designed for precision measurement of earth leakage currents, providing essential diagnostics in electrical installations and equipment. It is particularly engineered with a high sensitivity range, offering resolutions down to 0.01 mA, which is ideal for detecting very low earth leakage currents that could be causing protective devices like Residual Current Devices (RCD) or Ground Fault Circuit Interrupters (GFCI) to trip.

This clamp meter is fully compliant with EMC (Electromagnetic Compatibility) standards and meets the rigorous requirements of IEC61010-2-032, ensuring that it is safe and reliable for use in various electrical testing environments. Its capability to measure currents across a broad spectrum — with ranges of 30 mA, 300 mA, 30 A, and 300 A — makes the DCM300E highly versatile. Whether checking for leakage in circuits to troubleshoot nuisance trips of RCDs or GFCIs, or for general AC current measuring, this meter handles tasks with accuracy and ease.

The DCM300E features a 40 mm jaw size, which is optimally designed to clamp around cables and conductors in dense wiring environments comfortably. It combines both an analogue bar graph and a digital display, providing dual-mode visualization of measurements that enhance readability and user experience. The analogue bar graph is especially useful in observing fluctuations and trends in current flow, allowing for real-time monitoring and faster decision-making.

Megger DCM300E-Earth Leakage Clamp Meter Specifications:

  • Measuring Method: Dual integration mode
  • Measuring Function: Leakage current and load current
  • Display: 3,5 digit L.C.D.; max. reading of 3200
  • Range: 0-30 mA/300 mA/30 A/300 A (50/60Hz)
  • Ranging: 2 manual ranges.
  • Accuracy specified at operating temperature: 23°C ± 5°C, 80% RH max.
  • Range Min. Resolution Accuracy
    30/300 mA 0,01/0,1 mA ±1,2% rdg ±5 dgt
    0-200 A: ±1,2% rdg ±5 dgt.
    30/300 A 0,01/0,1 A 200-250 A: ±3,0% rdg ±5 dgt
    250-300 A: ±5,0% rdg ±5 dgt
  • Jaw Opening Capability: 40 mm
  • Over Range Indication: “OL” mark on L.C.D.
  • Maximum Indication: 3200
  • Low Battery Indication: 2,5 V – 2,7 V; “+-” mark on L.C.D.
  • Data Hold Indication: “DH” mark on L.C.D.
  • Sampling Time: Approx. 2 times/sec.
    (digital display)
  • Approx. 12 times/sec.
    (bargraph display)
  • Auto Power Off: The meter is set to power off
  • mode approx. 10 minutes after the
  • power switch on
    Limitation of Circuit Voltage: Less than a.c. 600 V
  • Withstanding Voltage: a.c. 3700 V/1 minute max.
    (between the core of CT and the unit housing)
  • Operating Temperature: 0 – 40 °C <80% RH
    (non-condensing).
  • Storage Temperature: -10 – 60 °C <70% RH
    (non-condensing).
  • Power Supply: 2 x 1,5 V button cells LR44 or SR 44
  • Power Consumption: Approx. 5 mW
  • Battery Life: Approx. 50 hrs. (LR44).
  • Size: 64 (W) x 176 (H) x 23 (D) mm
    2,5 (W) x 7 (H) x ,9 (D) inches
  • Weight: Approx. 125 g (1⁄4 lb. approx.
Related Product

If you’re looking for another similar product click the link below:

5
1 review
1
0
0
0
0

1 review for Megger DCM300E-Earth Leakage Clamp Meter

Clear filters
  1. Scarlett

    Works well and a must-have tool for an electrician

Add a review

Brand

Megger

Megger

Megger since 1889 is a leading global premium manufacturer of measurement and testing technology. Megger top priority has always been to make your everyday work easier and safer. As such, insulation testers, micro-ohmmeters, and multimeters are among the long line of Megger inventions, making this brand one of the pioneers in the electrical industry. Megger products combine many years of experience and the valued feedback from our global users with the inventiveness and conscientiousness of our product developers. In Germany, we manufacture at three sites, Aachen, and Baunach near Bamberg and Radeburg near Dresden. Other manufacturing locations are based in Sweden, England, and America.

megger

Data Sheet

Data Sheet

Specifications

SpecificationDetail
Measuring MethodDual integration mode
Measuring FunctionLeakage current and load current
Display3.5 digit L.C.D.; max. reading of 3200
Range0-30 mA/300 mA/30 A/300 A (50/60Hz)
Ranging2 manual ranges
AccuracySpecified at operating temperature: 23°C ± 5°C, 80% RH max.
Range Min. Resolution Accuracy30/300 mA 0.01/0.1 mA ±1.2% rdg ±5 dgt
0-200 A: ±1.2% rdg ±5 dgt.
30/300 A 0.01/0.1 A 200-250 A: ±3.0% rdg ±5 dgt
250-300 A: ±5.0% rdg ±5 dgt
Jaw Opening Capability40 mm
Over Range Indication“OL” mark on L.C.D.
Maximum Indication3200
Low Battery Indication2.5 V – 2.7 V; “+-” mark on L.C.D.
Data Hold Indication“DH” mark on L.C.D.
Sampling TimeApprox. 2 times/sec. (digital display)
Approx. 12 times/sec. (bargraph display)
Auto Power OffThe meter is set to power off mode approx. 10 minutes after the power switch on
Limitation of Circuit VoltageLess than a.c. 600 V
Withstanding Voltagea.c. 3700 V/1 minute max. (between the core of CT and the unit housing)
Operating Temperature0 – 40 °C <80% RH (non-condensing)
Storage Temperature-10 – 60 °C <70% RH (non-condensing)
Power Supply2 x 1.5 V button cells LR44 or SR 44
Power ConsumptionApprox. 5 mW
Battery LifeApprox. 50 hrs. (LR44)
Size64 (W) x 176 (H) x 23 (D) mm / 2.5 (W) x 7 (H) x .9 (D) inches
WeightApprox. 125 g (1/4 lb. approx.)

 