Back to products
Fluke 1555 FC Insulation Tester Kit
Fluke 1555 FC Insulation Tester Kit Original price was: AED 20,000.Current price is: AED 16,500. (excl.VAT)
-18%

Fluke 1550C Insulation Tester -5kv

The Fluke 1550C FC 5 kV Digital Insulation Tester performs digital insulation testing up to 5 kV, and makes data collection easy through the Fluke Connect™ wireless app.

(2 customer reviews)
SKU:3133

MME Shopping Event

Hurry and get discounts on Most of MME Products up to 20%

Original price was: AED 15,900.Current price is: AED 12,999. (excl.VAT)

1 in stock

15People watching this product now!

Fluke 1550C Insulation Tester – (5 kv)

Fluke 1550C Insulation Tester performs digital insulation testing up to 5 kV, and makes data collection easy through the Fluke Connect™ wireless app. Remote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone, rather than a hard-to-read set of changing values.

And you can create reports quickly, using pre-designed templates that you can customize with company logos. It’s the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. It comes with a three-year warranty and CAT IV 600 V safety rating.

Fluke 1550C Insulation Tester Applications: Where Precision Matters

The Fluke 1550C Insulation Tester is a versatile and essential tool used in various industries where precision and safety are paramount. Its applications span across a range of fields, including:

  1. Electrical Engineering: The Fluke 1550C is frequently employed in electrical engineering to test the insulation resistance of wires, cables, and electrical systems. This ensures the safety and reliability of electrical installations.
  2. Power Generation: In power generation facilities, the insulation resistance tester is used to assess the condition of high-voltage equipment, such as transformers and generators, to prevent electrical breakdowns and accidents.
  3. Industrial Maintenance: Manufacturing plants and industrial facilities use the Fluke 1550C to maintain and troubleshoot electrical systems, ensuring uninterrupted production processes.
  4. Telecommunications: The tester is crucial in the telecommunications industry for assessing the insulation resistance of communication cables, preventing signal loss and service interruptions.
  5. Renewable Energy: In the renewable energy sector, the Fluke 1550C helps maintain the integrity of solar panel installations and wind turbine systems, ensuring their long-term efficiency.
  6. Building Maintenance: Building managers and maintenance personnel use the tester to evaluate the insulation of wiring systems, reducing fire hazards and ensuring building safety.
  7. Aerospace: The aviation industry relies on the Fluke 1550C for testing electrical systems in aircraft, where safety and reliability are of utmost importance.
  8. Research and Development: Laboratories and research institutions use the tester to evaluate the insulation of prototypes and experimental electrical systems.
  9. Utilities: Utility companies use the Fluke 1550C to verify the insulation resistance of power distribution networks, guaranteeing a stable power supply.
  10. Oil and Gas: In the oil and gas industry, the tester ensures the safety and reliability of electrical systems in refineries, drilling operations, and pipelines.

Fluke 1550C Insulation Tester applications are diverse and crucial in maintaining the safety and reliability of electrical systems across various sectors. Its precision and ability to detect insulation issues make it an invaluable tool for professionals in these fields.

Understanding Fluke 1550C Insulation Tester Calibration

Fluke 1550C calibration is a critical process used to verify and adjust the accuracy of Fluke’s 1550C insulation resistance testers. These testers are renowned for their precision, making them a popular choice for professionals in various industries. Calibration ensures that the instrument continues to provide accurate and reliable measurements, which is vital for maintaining the quality and safety of your work.

Calibrating the Fluke 1550C involves comparing its readings to a known, traceable standard to detect any discrepancies. These discrepancies are then adjusted, guaranteeing that the instrument provides accurate readings. The calibration process not only safeguards the quality of your measurements but also complies with industry standards and regulations.

The Fluke 1550C Insulation Tester Calibration Process

Calibrating the Fluke 1550C involves a series of meticulous steps:

  1. Preliminary Inspection: Before calibration begins, the instrument is thoroughly inspected for any physical damage or defects.
  2. Zero Adjustment: The technician ensures that the instrument reads zero ohms when the test leads are shorted, guaranteeing accurate measurements.
  3. Functional Testing: The Fluke 1550C is tested for proper functionality, including the insulation resistance test, voltage measurement, and more.
  4. Calibration Data Collection: Precise measurements are taken at various points to create calibration data.
  5. Adjustment: If discrepancies are found, adjustments are made to bring the instrument’s readings in line with the standards.
  6. Verification: The instrument is retested to verify that it now meets the specified standards.
  7. Documentation: A calibration certificate is issued, detailing the instrument’s condition before and after calibration.

Benefits of Fluke 1550C Insulation Tester Calibration

Calibrating your Fluke 1550C Insulation Tester offers numerous benefits:

  1. Accuracy: Calibration ensures that your measurements are precise, reducing errors and inaccuracies.
  2. Compliance: It helps you meet industry standards and regulatory requirements.
  3. Quality Assurance: Calibrated instruments contribute to the overall quality and safety of your work.
  4. Longevity: Regular calibration extends the lifespan of your Fluke 1550C, protecting your investment.
  5. Reliability: Calibrated instruments are more reliable, reducing the risk of equipment failure.

Fluke 1550C Insulation Tester Manual: Your Comprehensive Guide

the Fluke 1550C Insulation Tester manual is an essential resource for anyone using this insulation resistance tester. This manual contains detailed instructions on how to operate, maintain, and troubleshoot the instrument. Here’s what you can typically find in the Fluke 1550C manual:

  1. Introduction: An overview of the instrument, its applications, and the importance of proper usage.
  2. Safety Precautions: Information on safety guidelines to ensure secure operation.
  3. Instrument Description: Detailed explanations of the tester’s components and how they function.
  4. Operating Instructions: Step-by-step guides on how to use the Fluke 1550C for various types of insulation resistance tests.
  5. Maintenance and Calibration: Recommendations on how to keep the instrument in optimal condition and when to perform calibration.
  6. Troubleshooting: Common issues and their solutions to help you address problems promptly.
  7. Technical Specifications: Detailed technical information about the instrument’s capabilities.
  8. Warranty and Support: Information on the instrument’s warranty and how to reach customer support.

The Fluke 1550C manual is an invaluable resource to ensure you get the most out of your insulation resistance tester while maintaining safety and precision. It’s crucial to read and understand this manual thoroughly before using the Fluke 1550C. If you have any specific questions about the manual or need assistance with a particular aspect of it, feel free to ask for further guidance.

Fluke 1550C Insulation Tester Price: What to Expect

you can always check Fluke 1550c price at our site in usd and AED.

MME-ae: One of the leading measuring tools distributors in Dubai

As the foremost distributor of all measuring and precision tools in Dubai, mme-ae.com takes pride in offering the most extensive range measuring tools  and monitoring products. Our online store ensures not only the most competitive prices but also includes a comprehensive warranty and post-sale service, coupled with complimentary training. For all your purchasing, selling, and inquiries regarding the application and pricing of Fluke 1550C FC 5 kV Digital Insulation Tester, please visit our website.

Fluke 1550C Insulation Tester specifications:

  • General Specifications:
  • Display:75 x 105 mm
  • Power:12 V lead-acid rechargeable battery, Yuasa NP2.8-12
  • Charger Input (AC):85 V to 250 V AC 50/60 Hz 20 VA
  • Dimensions:269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
  • Weight:3.7 kg (8.2 lb)
  • Temperature (operating):-20°C to 50°C (-4°F to 122°F)
  • Temperature (storage):-20°C to 65°C (-4°F to 149°F)
  • Humidity:80% to 31°C decreasing linearly to 50% at 50°C
  • Altitude:2000 m
  • Enclosure sealing:IP40
  • Input overload protection:1000 V AC
  • Electromagnetic compatibility:EN 61326
  • Safety compliance:IEC 61010-1: Overvoltage category II, Pollution Degree 2.
    IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III
    IEC 61557-1, IEC 61557-2

جهاز اختبار العزل الرقمي فلوك 1550C FC بجهد 5 كيلو فولت.

جهاز فلوك 1550C يقوم بإجراء اختبار العزل الرقمي حتى 5 كيلو فولت، ويجعل جمع البيانات أمرًا سهلاً من خلال تطبيق فلوك كونيكت اللاسلكي. التشغيل عن بعد يتيح لك قضاء أقل وقت ممكن في المناطق الخطرة بشكل محتمل. يظهر الاتجاه الزمني في الوقت الفعلي مخططًا حيًا على هاتفك، بدلاً من مجموعة من القيم المتغيرة الصعبة القراءة.

ويمكنك إنشاء تقارير بسرعة باستخدام قوالب مُصممة مُسبقًا يمكنك تخصيصها بشعارات الشركة. إنه الأداة المثالية لبرامج الصيانة التنبؤية أو التحفظية مصممة للكشف عن فشل المعدات المحتمل قبل حدوثه. يأتي مع ضمان لمدة ثلاث سنوات وتصنيف سلامة CAT IV 600 فولت.

How often should I calibrate my Fluke 1550C insulation resistance tester?

Calibration frequency depends on factors like usage and industry standards. Typically, annual calibration is recommended, but more frequent calibrations may be needed for critical applications.

Can I calibrate the Fluke 1550C myself?

While some users can perform basic checks, professional calibration is recommended to ensure accuracy and compliance.

What happens if I don't calibrate my Fluke 1550C?

Without calibration, your instrument may provide inaccurate readings, potentially compromising the quality and safety of your work.

How can I find a reliable calibration service for my Fluke 1550C?

Look for accredited calibration labs with a proven track record of accuracy and compliance with industry standards.

Is calibration only necessary for new instruments?

No, even well-maintained instruments require periodic calibration to ensure continued accuracy.

Can I use a third-party service for Fluke 1550C calibration?

Yes, as long as the calibration service is accredited and follows industry standards.

4.5
2 reviews
1
1
0
0
0

2 reviews for Fluke 1550C Insulation Tester -5kv

Clear filters
  1. Samuel

    Fluke has always been my best

  2. martin spielberg

    Value for money
    Durability
    Delivery speed

    What are the key features and benefits of the Fluke 1550C FC 5 kV Digital Insulation Tester?

    • Store managerbehruzshy2015

      The Fluke 1550C FC 5 kV Digital Insulation Tester is a robust and versatile tool for testing insulation resistance in electrical systems. It stands out with its 5 kV output, digital display for accurate measurements, and Fluke Connect compatibility for wireless data transfer. Safety features like automatic discharge and voltage alarms enhance user security. The device offers precision, long battery life, and the ability to measure voltage, resistance, and capacitance. Its rugged design ensures durability in industrial settings. Overall, the 1550C FC is a trusted choice for professionals in the electrical and industrial fields, providing reliable measurements, data management, and safety.
      We sent more info about Fluke 1550C FC 5 kV Digital Insulation Tester to your email

Add a review

Brand

Fluke

Fluke Corporation

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products. From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Specification table

Specifications
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
OhmsRange/resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode testRange/resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/resolution> 1000 μF
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A continuous overload for 30 seconds max
DC ampsRange/resolution6.000 A / 0.001 A   10.00 A / 0.01 A
Accuracy1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Data Sheet

Data Sheet

Specifications

1 in stock